You are here: Home page > Product > Gas boiler >

WNS series automatic fuel (gas) steam (hot water) boiler)

Gas boiler2021-05-17 13:32

WNS series automatic fuel (gas) steam (hot water) boiler)

Time:2021-05-17 13:32

Describe:

The 0.5-20t/h (0.35-14MW) fuel (gas) steam and hot water boiler produced by the company adopts a fully wet back structure and high-efficiency heat transfer elements, as well as matching burners and fully automatic control equipment. The boi...

Detail
The 0.5-20t/h (0.35-14MW) fuel (gas) steam and hot water boiler produced by the company adopts a fully wet back structure and high-efficiency heat transfer elements, as well as matching burners and fully automatic control equipment. The boiler adopts a horizontal internal combustion three-pass full wet back structure. The fuel (gas) is burned by the burner, and the high-temperature flue gas after combustion is radiated and convectively exchanged by the furnace smoke chamber, and then enters the second return threaded smoke pipe, folds from the front smoke box and then enters the third return smoke pipe, and finally passes through the rear smoke box. , Energy saver, discharged from the chimney.
Features:
1. The combustion chamber adopts a corrugated furnace, which increases the heating area, strengthens heat transfer, and has good thermal expansion characteristics. The small smoke chamber adopts a wet back structure, and the high-temperature flue gas is surrounded by the water space, which eliminates the phenomenon of cracks in the boiler tube plate due to thermal fatigue.
2. The smoke pipe adopts the combined structure of threaded tube and smooth tube. The second return pass with higher smoke temperature adopts the threaded tube, and the third return pass with lower smoke temperature adopts the smooth tube to enhance the heat transfer and make the smoke resistance at a suitable level. Within range.
3. The boiler tube plate and the smoke tube are automatically welded by argon arc welding in all positions to ensure the welding quality.
4. It has a rich heating surface and a large enough water space and steam space to ensure the stability of the boiler parameters.
5. The boiler adopts high thermal resistance material and closed metal outer cover as the thermal insulation layer, which has good thermal insulation performance.
6. There are manholes on the top of the boiler; there are hand holes on the lower side for easy inspection. There are fire-viewing holes on the front and back of the boiler to observe the combustion situation in the furnace.
7. The front smoke box adopts high-aluminum high-temperature resistant paint to protect the insulation material from being carried away by the smoke.
8. The boiler is equipped with imported burners, which has high combustion efficiency, and has the functions of ignition program control and overpressure flameout protection.
9. The boiler feed water is automatically controlled and has a multi-level alarm protection function
Technical parameters of WNS series automatic fuel (gas) steam boiler
Serial number Product number Rated evaporation
t/h
Work pressure
MPa
exhaust temperature
Water supply
temperature
Steam temperature
Maximum transport
weight
t
Design thermal efficiency % Dimensions
mm
1 WNS0.5-1.0-Y、Q 0.5 1.0 139.6(70) 20 184 3.8 92.3 (97.2) 3750x2650
x1840
2 WNS1-1.0-Y、Q 1 1.0 153(70) 20 184 5 92.3 (97.3) 4200x2400
x3020
3 WNS2-1.25-Y、Q 2 1.25 130.1(70) 20 194 8.8 93.4 (97.2) 5300x3000
X2600
4 WNS3-1.25-Y、Q 3 1.25 156(70) 20 194 12 94 (97.3) 5600x2700
X2800
5 WNS4-1.25-Y、Q 4 1.25 133.7(70) 20 194 12 93.2(97.2) 6200x3000
X2900
6 WNS5-1.25-Y、Q 5 1.25 124.7(70) 20 194 16.1 93.1(97.3) 7100x2600
X3100
7 WNS6-1.25-Y、Q 6 1.25 131(70) 20 194 16.8 92.8(97.2) 6700x2800
x3100
8 WNS8-1.6-Y、Q 8 1.6 158(70) 20 204 19 92.8(97.3) 5900x2800
x3200
9 WNS10-1.6-Y、Q 10 1.6 152(70) 20 204 21 92.3 (97.2) 6600x2800
x3200
10 WNS15-1.25-Y、Q 15 1.25 130(70) 104 194 37.5 93.1 (97.3) 1230x4000
x3800
11 WNS20-1.25-Y、Q 20 1.25 152(70) 104 194 60 92.6(97.2) 8070x3500
x3700
Note: 1. The rated pressure of 1.0, 1.25, 1.6, 2.5MPa can be selected for boilers of various capacities.
        2. Exhaust flue gas temperature and design thermal efficiency The data in brackets are the parameters after the boiler is equipped with a condenser.
        3. When the NOx emission requirement is lower than 80mg/Nm³ or 30mg/Nm³, the boiler size is detailed in the drawings.
Technical parameters of WNS series automatic fuel (gas) hot water boiler 
Serial number Product number Rated heat supply
t/h
Work pressure
MPa
Outlet temperature
Backwater
temperature
exhaust temperature
Maximum transport
weight
t
Design thermal efficiency % Dimensions
mm
1 WNS0.35-0.7/95/70-YLIQ 0.35 0.7 95 70 153.9(70) 3.8 92.3 (97.2) 3200x1400
x1900
2 WNS0.7-0.7/95/70-YLIQ 0.7 0.7 95 70 155(70) 4.7 92.1 (97.3) 3400x1800
X2400
3 WNS1.4-1.0/95/70-YLIQ 1.4 1.0 95 70 144.8(70) 8.2 93
(97.2)
5100x2100
X2600
4 WNS2.1-1.0/110/70-YLIQ 2.1 1.0 110 70 155(70) 10.6 92.2 (97.3) 4830x2250
X2850
5 WNS2.8-1.0/95/70-YLIQ 2.8 1.0 95 70 155.5(70) 11.9 92.2
(97.2)
6000x2700
X2800
6 WNS4.2-1.0/95/70-YLIQ 4.2 1.0 95 70 159.7(70) 17.4 92
(97.3)
6700x2700
X3000
7 WNS5.6-1.0/95/70-YLIQ 5.6 1.0 95 70 156.5(70) 18.6 92.1
(97.3)
6700x2800
x3200
8 WNS7-1.25/130/70-YLIQ 7 1.25 130 70 157(70) 19.6 93
(97.2)
6650x2750
x3280
9 WNS10.5-1.25/130/70-YLIQ 10.5 1.25 130 70 156(70) 37.1 92.5 (97.3) 7250x3300
x3670
10 WNS14-1.25/130/70-YLIQ 14 1.25 130 70 156(70) 58.2 93.2 (97.2) 8070x3500
x3900
Note: 1. The rated pressure of 1.0, 1.25, 1.6MPa can be selected for boilers of various capacities, and the temperature can be selected from 95℃, 110℃, 115℃, 130℃, etc.
        2. Exhaust flue gas temperature and design thermal efficiency The data in brackets are the parameters after the boiler is equipped with a condenser.
        3. When the NOx emission requirement is lower than 80mg/Nm3 or 30mg/Nm3, the boiler size is detailed in the drawings.

 


Consult